    "Chris Cole" <> writes:

    > One of the points made by Ted Sealy from Sprint is that they take
    > advantage of the extra link budget in 10GBASE-LR 10km link budget to
    > account for extra connector loss, etc.

    Ted Seely and I are of the same mind on this. 2 dB sounds like plenty
    for connector loss right up until you have to deal with multiple patch
    bays in a structured system with amateurishly applied mechanical
    splices. The difference between noting that the loss is a little high
    but the link still works so you roll with it, and having to spend time
    on the phone arguing with someone who thinks 24 dB link loss is A-OK,
    will make the slight additional up front cost for the better grade
    optics look very inexpensive indeed...

    > From this discussion it sounds to me like we should stick with 10km
    > initially, and then later come back with an additional specification
    > optimized for low cost, perhaps covering 2km.

    I'm on board with that as far as it goes, but has the scenario of
    adjustable launch powers so that you don't ever need attenuators plus
    the economy of scale that would come from having *one* type of
    interface for 1m-10km runs been considered? It seems to me based on
    what I've seen of the optics market that once you make something a
    mass-produced commodity the price falls awfully far - suppose the
    price difference was $250 vs. $375, that's a big difference on a
    percentage basis but pocket change on an absolute basis.

                                            ---rob

    >
    > Chris
    >
    > -----Original Message-----
    > From: Robert E. Seastrom [mailto:]
    > Sent: Wednesday, December 12, 2007 5:06 AM
    > To: Justin M. Streiner
    > Cc: ; Chris Cole
    > Subject: Re: IEEE 40GE & 100GE
    >
    >
    > "Justin M. Streiner" <> writes:
    >
    >> I haven't read the draft spec yet to see what's being proposed for a
    >> link budget at 3/4/10km, but that's just as important as the physical
    >> distance.
    >
    > That's a really good point, and one which I didn't originally consider
    > pre-coffee. :-)
    >
    > Link budget information on page 4, here:
    > http://www.ieee802.org/3/hssg/public/reach/Matsumoto_r1_1207.pdf
    > Relative cost estimates on page 5.
    >
    > Suppositions for ingredients to link budget are here:
    > http://grouper.ieee.org/groups/802/3/hssg/public/nov07/cole_01_1107.pdf
    > (page 3)
    >
    > I'm kind of looking longingly at that extra 3dB, given the slight
    > marginal extra cost and my knowledge of the trained chimp quality
    > mechanical splices that are rife in certain <cough> data centers.
    >
    > ---Rob